Home / EVA Film leftover material waste recovery and re-granulation unit

EVA Film leftover material waste recovery and re-granulation unit

EVA RECYCLING LEFTOVER MATERIAL REGRANULEATION-04

The processing temperature of EVA is not high, one of which melts at 80-90 degrees.

I have two kinds of EVA raw materials at hand (leftover material, half transparent, and almost non-transparent).

EVA RECYCLING LEFTOVER MATERIAL REGRANULEATION-02

We use 150 diameters of single screw extruder to granulate. One is the low-temperature re-granulation, the temperature is set at about 80 degrees, the die heads temperature is set at 60 degrees, the water tank is equipped with chiller cooling, and the temperature is set at 26 degrees. The extrusion strip is perfect.


For another kind of opaque material, we have tried many times, but the results failed. The temperature setting is the same as the transparent material one, but it is not successful after many times testing. The material is either burnt out or degraded and foaming. This is what it looks like.

EVA RECYCLING LEFTOVER MATERIAL REGRANULEATION-00

I have been unable to extrude granulation, and I even began to wonder if there was something wrong with the original design of the extrusion machine:

1. Is the L/D ratio too long? L/D: 28:1

2. Single screw shafts didn’t design a water runner in the middle of the shafts for cooling?

EVA RECYCLING LEFTOVER MATERIAL REGRANULEATION-07

But if there is a problem, why the transparent EVA material could be re-granulation?

EVA RECYCLING LEFTOVER MATERIAL REGRANULEATION-05

Then it occurred to me that we could do the opposite and directly increase the temperature of the nose to about 150 degrees. The situation was completely changed and the material came out at once. Granulation is also perfect.

EVA RECYCLING LEFTOVER MATERIAL REGRANULEATION-08